Completed NCT07680530

SpO2 Verification Study - Philips Nasal Alar With Nellcor OxiMax SpO2 Board (453564624031)

Conditions: Pulse Oximetry

Sex: All
Ages: 18 Years – 50 Years
Healthy volunteers: Yes
Enrollment: 43
Sponsor: Philips Clinical & Medical Affairs Global

Location: Element Materials Technology Louisville Colorado

Summary

The primary purpose of the clinical investigation is to verify the SpO2 accuracy of the Philips AlarX5 SpO2 sensor with Nellcor OxiMax SpO2 Board.

Eligibility Criteria

Inclusion Criteria: * Participant must have the ability to understand and provide written informed consent * Participant is an adult between 18-50 years of age * Participant must be willing and able to comply with study procedures and duration * Participant is a non-smoker or who has not smoked within 2 days prior to the study Exclusion Criteria: * Participant is considered as being morbidly obese (defined as BMI \>39.5) * Compromised circulation (i.e., Raynaud's Syndrome), injury, or physical malformation of fingers, hands, nose, ears or forehead/skull or other sensor sites which would limit the ability to test sites needed for the study. Tattoos (e.g. permanent, Henna) or artificial dyes (e.g. spray tan, artificial tanning lotion) in the optical path which would limit the ability to test sites needed for the study. (Note: Certain malformations may still allow participants to participate if the condition is noted and would not affect the sites utilized.) * Females who are pregnant * Females who are trying to get pregnant with confirmation of positive urine pregnancy test * Participants who have smoked in the last 2 days or participants who have refrained, for at least 48 hours, with COHb levels \>3% as assessed with a Masimo Radical 7 (Rainbow) * Participants with known respiratory conditions such as: (self-reported) * uncontrolled / severe asthma * flu * pneumonia / bronchitis * shortness of breath / respiratory distress * unresolved respiratory or lung surgery * emphysema, COPD, lung disease * recent COVID with hospitalization * Participants with self-reported heart or cardiovascular conditions such as: (self-reported, except for blood pressure and ECG review) * high blood pressure: systolic \>140 mmHg or diastolic \>90 mmHg on 3 consecutive readings (reviewed during health screen) * have had cardiovascular surgery, except successful minor surgery without clinical symptoms (i.e., PFO, PDA) * chest pain (angina) * heart rhythms other than a normal sinus rhythm or with respiratory sinus arrhythmia (reviewed during health screen) * previous heart attack * blocked artery * unexplained shortness of breath * congestive heart failure (CHF) * history of stroke * transient ischemic attack * carotid artery disease * myocardial ischemia * myocardial infarction * cardiomyopathy * implantable active medical device such as pacemaker or automatic defibrillator * Participants with self-reported health conditions * diabetes * uncontrolled thyroid disease * kidney disease / chronic renal impairment, * history of seizures (except childhood febrile seizures) * epilepsy * history of unexplained syncope * recent history of frequent migraine headaches * recent symptomatic head injury (within the last 2 months) with continued symptoms * cancer requiring chemotherapy, radiation, or current treatment - Participants with known clotting disorders (self reported) * history of bleeding disorders or personal history of prolonged bleeding from injury * history of blood clots * hemophilia * current use of blood thinner: prescription or daily use of aspirin * Sickle Cell Trait or Disease - Participants with self-reported dermatological conditions at sensor application sites * severe dermatitis * hyperkeratosis * nail fungus - Participants with severe contact allergies to standard adhesives, latex, silicone or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors (self reported) * Participants with severe allergies to iodine (only applicable if iodine is used) * Participants with severe allergies to lidocaine (or similar pharmacological agents, e.g. Novocaine) * Participants with allergies to ultrasound gel * Failure of the Perfusion Index Ulnar/Ulnar+Radial Ratio test (Ratio \

Interested in this study? View the official listing for contact and enrollment details.