← Back to all trials
Completed
NCT07683039
Thyroid Fine Needle Biopsy and Impact on Pain and Diagnostic Adequacy
Conditions: Thyroid Nodular Disease
Sex: All
Ages: 18 Years – 88 Years
Healthy volunteers: No
Phase: NA
Enrollment: 169
Sponsor: Izmir Ataturk Training and Research Hospital
Location: İzmirAtatürk Training and Education Hospital Izmir
Summary
This randomized study compares patient pain and comfort during ultrasound-guided thyroid fine needle biopsy using 21-gauge versus 27-gauge needles. Patients with thyroid nodules were randomly assigned to one of two needle sizes. Pain intensity was measured immediately after the procedure using a 0-100 Visual Analog Scale. The study was conducted at İzmir Atatürk Training and Research Hospital between January 2024 and March 2024. The aim is to determine which needle size causes less pain and better patient comfort during the biopsy procedure.
Eligibility Criteria
Inclusion Criteria:
* Thyroid nodules requiring ultrasound-guided FNB with a maximum diameter ≥3 mm,
* Intraglandular nodules with relatively central location within the thyroid gland
Exclusion Criteria:
* Patient refusal to provide informed consent,
* History of bleeding tendency or use of anticoagulant medication,
* Substernal or subclavicular localization of the lesion in cases of large goiter.
Source: ClinicalTrials.gov (NCT07683039). StuddyBuddy aggregates publicly available trial information.